Specialized messages related to the performance of through-hole insertion equipment
Classes
  ClassDescription
Public classComponentsInserted
Sent periodically by an THT inserter to indicate the number of insertions which were successfully or unsuccessfully completed during the sample time window. This sample time window shall not exceed 10 minutes.
{
  "StartTime": "2018-04-06T08:06:46.4471059-04:00",
  "EndTime": "2018-04-06T08:16:46.4471059-04:00",
  "TotalComponentsInserted": 875,
  "TotalComponentsNotInserted": 45
}