Sent by a process endpoint when units physically depart from a process endpoint. This does not imply any information about any activity that may have taken place.
{
  "UnitCount": 2,
  "Units": [
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 1,
      "PositionName": "CIRCUIT1",
      "X": 0.254,
      "Y": 0.556,
      "Rotation": 0.0,
      "FlipX": false,
      "FlipY": false
    },
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 1,
      "PositionName": "CIRCUIT2",
      "X": 6.254,
      "Y": 0.556,
      "Rotation": 90.0,
      "FlipX": false,
      "FlipY": false
    }
  ]
}
Inheritance Hierarchy

Namespace:  CFX.Production
Assembly:  CFXnet46 (in CFXnet46.dll) Version: 1.0.5
Syntax
public class UnitsDeparted : CFXMessage

The UnitsDeparted type exposes the following members.

Properties
  NameDescription
Public propertyUnitCount
The number of individual production units
Public propertyUnits
List of structures that identify each specific instance of production unit that departed (could be within a carrier or panel).