Click or drag to resize

UnitsDisqualified Class

[This is preliminary documentation and is subject to change.]

Sent by a process endpoint to identify that a specific production unit is disqualified or scrapped. This includes logical disqualification in the case that a unit is abandoned during manufacturing
{
  "UnitCount": 2,
  "Units": [
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 1,
      "PositionName": "CIRCUIT1",
      "X": 0.254,
      "Y": 0.556,
      "Rotation": 0.0,
      "FlipX": false,
      "FlipY": false
    },
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 1,
      "PositionName": "CIRCUIT2",
      "X": 6.254,
      "Y": 0.556,
      "Rotation": 90.0,
      "FlipX": false,
      "FlipY": false
    }
  ]
}
Inheritance Hierarchy
SystemObject
  CFXCFXMessage
    CFX.ProductionUnitsDisqualified

Namespace:  CFX.Production
Assembly:  CFXnet46 (in CFXnet46.dll) Version: 1.0.5
Syntax
public class UnitsDisqualified : CFXMessage

The UnitsDisqualified type exposes the following members.

Properties
  NameDescription
Public propertyUnitCount
The number of individual production units
Public propertyUnits
List of structures that identify each specific instance of production unit to be disqualified (could be within a carrier or panel).